Data Center Overview

Our connectivity comes from multiple redundant 2000 Mbps GIG-E connections to the Internet via four of the largest tier-1 backbones in existence (including Qwest, AT&T, UUNET, Level3, Genuity, Time Warner and Yipes). All servers are housed in secure racks in an air-conditioned, static electricity controlled environment behind locked doors and full security system. They are protected by surge suppression and power management systems to ensure uninterrupted server operations. A professional team of highly trained technicians monitors the network 24/7/365 to guarantee smooth and uninterrupted operation of your site and server.

Connectivity
* Multiple, redundant high speed GIG-E connections designed not to exceed 60% capacity.
* Diverse upstream connectivity through multiple large Tier 1 providers.
* Diverse network gateway platform fully meshed for maximum uptime.
* Border Gateway Protocol (BGP) end-user intelligent routing software.

Power
* N+1 redundancy in all systems.
* 48V DC power plant with redundant "A" and "B" circuits.
* Single-point grounding system as required by the NEMA code.
* UPS output capacity engineered at 375 KVA.
* 4-hour Valve-Regulated Lead-Acid (VRLA) batteries.
* Backup generators with 24 x 7 national maintenance contract.

Security
* 24/7/365 on-site security staff.
* 24/7/365 national real time monitoring of all alarm and intrusion systems.
* Closed-circuit television surveillance system throughout facilities.
* Strict access control system covering all interior areas monitored and controlled.

Environment
* Custom HVAC design that supports the cooling loads required for data center.
* Raised flooring in the cabinet space for improved airflow. Cabinets are bolted into the main floor.
* State-of-the-art Building Management Systems monitored 24/7/365 from Network Operations Center.

Fire Protection
* Dry-Pipe, Pre-Action double interlock fire suppression system.
* The fire detection system consists of both smoke and high temperature heat detectors.
* Zone specific discharge.
* Early warning VESDA fire detection systems.

Servers (minimum specifications)
*  Dell Dual Pentium III 933Mhz processors
* 133MHz front side bus
* 36 Gig SCSI drive
* 1 Gig of 133MHz SDRAM memory with Error-Correcting Code
* Kernel version - 2.4.18-pre3
* Apache version - 1.3.26 (Unix)
* PERL version - 5.006001
* PHP version - 4.2.1
* MySQL version - 3.23.45

* Operating Systems
* RedHat Linux